Bulletin No.3
Date: March 11, 2015
Ref: PRT-2015-0059
Bid No.:CMIT-PRT-10.30-150027
Project Title: Perforated Pipes Purchasing for 5+6 Horizontal Wells
Subject: Technical & Commercial Clarification
Dear Potential Bidders,
In respect of the tender Perforated Pipes Purchasing for 5+6 Horizontal Wells (CMIT-PRT-10.30-150027), with reference to some bidders’ technical and commercial clarifications, CNOOC Iraq Limited hereby announces that there is the response as the attachments.
Note:
1.Tender Closing Date is extended to 17:00, on or before March 23, 2015 (Dubai Time).
2.All documents of ITT and bulletins of this Tender can be downloaded as the link below,
Thanks for your supporting and cooperation!
_________________________
Mr. Ma Peixin
Manager of contracts & procurement department
CNOOC Iraq Limited
Attachment: Company’s response to bidder’s technical & commercial clarification.
Appendix 1
PERFORATED PIPE PURCHASING FOR 5+6 HORIZONTAL WELLS
ITT No. CMIT-PRT-10.30-150027
Bidder’s 1# Question:
Please kindly confirm JFEBEAR premium connection is acceptable
Company’s Answer:
Regarding with JFE Bear Premium connection, kindly refer to our previous clarification response of Bulletin No.2 which is concerned with same query.
“You can submit this kind of connection proposal for our project. Accept or not will be up to technical evaluation committee”
Bidder’s 2# Question:
We would like to kindly request to extend another one (1) week for the tender closing date in an effort to provide our best and most competitive offer.
Company’s Answer:
Accepted.
Appendix 2
Regarding to the procurement project of PERFORATED PIPE PURCHASING FOR 5+6 HORIZONTAL WELLS, the supplementary crossovers need to be added into ITT and quoted by bidders, which has been attached as below:
Attachment:
Item |
Description |
QTY |
Unit |
Note |
1 |
Crossover Sub Max. OD: ≤ 4.937" Min. ID: 3.351" Top Connection: 4" 11.6ppf VAM TOP Box Bottom Connection: 4-1/2” OD 12.6ppf Vam FJL Pin Metallurgy:L80-13CR Length:6ft
*Note: it shall be located in between Company’s 4” Perf. Tbg. Jts VAM TOP Pipe B*P and Company’s 4-1/2” 12.6lb/ft VAM FJL Box x Pin o-ring seal sub |
10 |
EA |
|
2 |
Crossover Sub Max. OD: ≤ 4.937" Min. ID: 3.95" Top Connection: 4-1/2” OD 12.6ppf Vam FJL Box Bottom Connection: 4-1/2” OD 12.6ppf JFE BEAR Pin Metallurgy:L80-13CR Length: 6ft
* Note: it shall be located in between Company’s o-ring seal sub 4-1/2” 12.6lb/ft VAM FJL Box x Pin and Company’s 4 ½” guide shoe with float. |
10 |
EA |
|